We inspected the caster structures for corrosion including all support steel, floor steel, equipment supports, run-out tables, exposed foundations, concrete floors and handrail. Ultrasonic testing was used in order to determine the degree of corrosion. Once the inspection was complete we provided a detailed report prioritizing the areas that were in need of repair or monitoring. The report also included repair details where necessary.